Strong Short-Circuit Resistance Scb11 Series 2000 kVA Electrical Dry Type Transformer
Product Details
| Customization: | Available |
|---|---|
| Application: | Power, Electronic, Instrument, Lighting, Rectifier, Audio |
| Phase: | Single |
Manufacturer/Factory & Trading Company
360° Virtual Tour
Diamond Member Since 2025
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
High Repeat Buyers Choice
ODM Services
Product Certification
Quality Assurance
More than 50% of buyers repeatedly choose the supplier
The supplier provides ODM services
The supplier's products already have relevant certification qualifications, including:
Product Certificate
Product Certificate
Product Certificate
Type II CQC Certification
Product Certificate
Product Certificate
Product Certificate
Type II CQC Certification
The supplier provides quality assurance
Sign In to see all verified strength labels (25)
Find Similar Products
Basic Info.
- Model NO.
- SCB11 Series Dry Transformer
- Core
- Core-type Transformer
- Cooling Method
- Dry-type Transformer
- Winding Type
- Separated Winding Transformer
- Certification
- ISO9001-2000, ISO9001, CCC
- Usage
- Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
- Frequency Characteristics
- Power Frequency
- Shape of Core
- OD
- Product Name
- Dry Type Transformer
- Keywords
- Dry Type Transformer
- Model
- Scb30,Scb50,Scb80,Scb100,Scb125,etc.
- Rated Capacity (kVA)
- 30 - 2500
- Link Group Label
- Yyn0 or Dyn11
- High Pressure
- 10 / 6.3 / 6
- Low Pressure
- 0.4
- No-Load Loss (W)
- 170 - 3240
- Load Loss(W)120℃(F)
- 710 - 18800
- No-Load Current(%)
- 2 / 1.5 / 1.3 / 1.1 / 1 / 0.85 / 0.7
- Short Circuit Impedance(%)
- 4 / 6 / 8
- MOQ
- Low MOQ
- Sample
- Accept
- OEM & ODM Custom
- Accept
- Logo Custom
- Accept
- Transport Package
- Standard Shipping Packaging or Customized
- Specification
- Standard Specifications Or Customized
- Trademark
- PENG TAI
- Origin
- Jiangsu, China
- Production Capacity
- 5000000set/Year
Product Description
DRY TYPE TRANSFORMER
It has the advantages of strong short-circuit resistance, low maintenance workload, high operating efficiency, small size, and low noise. It is used in places with high performance requirements, such as fire prevention and explosion prevention.
It is safe, fireproof, and pollution-free and can be directly operated in high-load electricity.It adopts advanced domestic technology with high mechanical strength, strong short-circuit resistance, small partial discharge, good thermal stability, high reliability, and long service life.
It has the advantages of strong short-circuit resistance, low maintenance workload, high operating efficiency, small size, and low noise. It is used in places with high performance requirements, such as fire prevention and explosion prevention.
It is safe, fireproof, and pollution-free and can be directly operated in high-load electricity.It adopts advanced domestic technology with high mechanical strength, strong short-circuit resistance, small partial discharge, good thermal stability, high reliability, and long service life.
Low loss, low noise, obvious energy saving effect, and maintenance-free.
| Technical Parameter | |||||||||
| Model | Rated Capacity | Link Group Label | Voltage Combination (KV) | No-Load Loss | Load Loss(W) | No-Load Current | Short Circuit Impedance | ||
| (KVA) | High Pressure | Tap Range | Low Pressure | (W) | 120ºC(F) | (%) | (%) | ||
| SC11-30 | 30 | Yyn0 or Dyn11 |
10 6.3 6 |
±5% ±2×2.5% or +3/-1×2.5 |
0.4 | 170 | 710 | 2 | 4 |
| SC11-50 | 50 | 240 | 1000 | 2 | 4 | ||||
| SC11-80 | 80 | 330 | 1380 | 1.5 | 4 | ||||
| SC(B)11-100 | 100 | 360 | 1570 | 1.5 | 4 | ||||
| SC(B)11-125 | 125 | 420 | 1850 | 1.3 | 4 | ||||
| SC(B)11-160 | 160 | 480 | 2130 | 1.3 | 4 | ||||
| SC(B)11-200 | 200 | 550 | 2530 | 1.1 | 4 | ||||
| SC(B)11-250 | 250 | 640 | 2760 | 1.1 | 4 | ||||
| SC(B)11-315 | 315 | 790 | 3470 | 1 | 4 | ||||
| SC(B)11-400 | 400 | 880 | 3990 | 1 | 4 | ||||
| SC(B)11-500 | 500 | 1040 | 4880 | 1 | 4 | ||||
| SC(B)11-630 | 630 | 1200 | 5880 | 0.85 | 4 | ||||
| SC(B)11-630 | 630 | 1170 | 5960 | 0.85 | 6 | ||||
| SC(B)11-800 | 800 | 1360 | 6960 | 0.85 | 6 | ||||
| SC(B)11-1000 | 1000 | 1590 | 8130 | 0.85 | 6 | ||||
| SC(B)11-1250 | 1250 | 1880 | 9690 | 0.85 | 6 | ||||
| SC(B)11-1600 | 1600 | 2200 | 11700 | 0.85 | 6 | ||||
| SC(B)11-2000 | 2000 | 2740 | 14400 | 0.7 | 6 | ||||
| SC(B)11-2500 | 2500 | 3240 | 17100 | 0.7 | 6 | ||||
| SC(B)11-1600 | 1600 | 2200 | 12900 | 0.85 | 8 | ||||
| SC(B)11-2000 | 2000 | 2740 | 15900 | 0.7 | 8 | ||||
| SC(B)11-2500 | 2500 | 3240 | 18800 | 0.7 | 8 | ||||
FEATURES-1
Good heat dissipation, strong overload capacity, and can be operated at over capacity for a short time under forced air cooling.
Good heat dissipation, strong overload capacity, and can be operated at over capacity for a short time under forced air cooling.
FEATURES-2
It has a certain moisture-proof performance and can operate in harsh environments with high humidity.
It has a certain moisture-proof performance and can operate in harsh environments with high humidity.
FEATURES-3
Dry-type transformers can be equipped with a complete temperature detection and protection system. The intelligent signal temperature control system can automatically detect and display the operating temperature of each three-phase winding, automatically start and stop the fan, and has alarm, trip, and other function settings.
Dry-type transformers can be equipped with a complete temperature detection and protection system. The intelligent signal temperature control system can automatically detect and display the operating temperature of each three-phase winding, automatically start and stop the fan, and has alarm, trip, and other function settings.
FEATURES-4
Small size, light weight, less space, and low installation cost.
Small size, light weight, less space, and low installation cost.
FEATURES-5
Safe, fireproof, pollution-free, can be directly operated under high load electricity.
Safe, fireproof, pollution-free, can be directly operated under high load electricity.

Q: Are you a manufacturer, factory, or trading company?
A: We have our factory.
Q: What are your warranty terms?
A: We provide a 12-month warranty.
Q: Production time?
A: Generally it takes 4 to 6 weeks, depending on different styles.
Q: What are your payment terms?
A: T/T and L/C payments can be accepted.
Q: How do you do quality control in your factory?
A: We implement 100% quality control inspection to ensure that each product is qualified. We have more than 10 quality control inspections during the manufacturing process from raw materials to final products. Each of our units has 3C certificates. If you need any other certificates, we can help you apply for them.
Q: Do you have products in stock?
A: Usually no. All our products are produced according to your order quantity.
Q: What do I need to provide for a custom transformer?
A: It is better to provide technical drawings and technical specification documents, or you can tell us some detailed technical specifications date as shown below "Information required for quotation and ordering.
Send your message to this supplier
People who viewed this also viewed
Product Groups
Find Similar Products By Category
- Supplier Homepage
- Products
- Dry Type Transformer
- SCB11
- Strong Short-Circuit Resistance Scb11 Series 2000 kVA Electrical Dry Type Transformer
Related Categories
Hot Searches
- Power Transformer Factories
- Voltage Transformer Factories
- China Transformer Factories
- Electrical Transformer Factories
- U Electrical Power Transformer
- Three Electrical Power Transformer
- Electronic Electrical Power Transformer
- Electrical Distribution Transformer
- Power Frequency Electrical Transformer
- Dry Transformer Bulkbuy
More